Voltage: | Low and Medium Voltage Cable |
---|---|
Current: | AC Cable |
Insulation Material: | XLPE |
Sheath Material: | PVC |
Material Shape: | Round Wire |
Wire Core Material: | Red Copper Wire |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Type | Name | Temperature index (ºC) |
Remarks |
MYFB | Single polyimide fluorine 46 composite thin film wrapped copper flat wire |
200 | Domestic film |
MYFEB | Double polyimide fluorine 46 composite thin film wound copper flat wire |
200 | Domestic film |
MYFB | Single polyimide fluorine 46 composite thin film wrapped copper flat wire |
220 | DuPont film |
MYFEB | Double polyimide fluorine 46 composite thin film wound copper flat wire |
220 | DuPont film |
Item | Technical requirements | Test methods | |
Size | As shown in article of GB6108.3 |
GB/T 4074.2 | |
Insulation thickness |
As shown in article 4.3 of GB6757 |
GB/T 4074.2 | |
Resistivity | ρ≤0.017241 Ω*mm2/m when the copper conductor is with temperature at 20ºC |
GB/T 3048.2 | |
Elongation | Nominal size (mm) |
Elongation % |
GB/T 4074.3 |
a≤2.50 2.5 | ≥30 ≥33 | ||
Resilience | The maximum rebound angle should be no more than 5 degrees |
GB/T 4074.3 | |
Bending | Samples were 4 times and 4 times in the broad narrow size bar on the narrow side and the broad side bending, the insulating layer should not crack or delamination |
GB/T 4074.3 |
Suppliers with verified business licenses